Application
These cables are used for fixed installations on ships and offshore units in all locations and on open deck. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are flame retardant, low smoke & halogen free.
Standards
DIN 89160/98
IEC 60092-353
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction
Conductors: Class 2 stranded copper conductor.
Insulation: HEPR.
Overall Screen: Copper wire braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Single core: Natural colour (beige).
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 6×OD
Temperature Range: -20℃ ~ +75℃
Dimensions and Weight
Part No. |
Construction |
Nominal Insulation |
Nominal Sheath Thickness mm |
Nominal Overall |
Nominal Weight kg/km |
MTX300-1G7MZ1-R-1C4 |
1×4 |
0.7 |
1.2 |
7.3 |
110 |
MTX300-1G7MZ1-R-1C6 |
1×6 |
0.7 |
1.2 |
8.3 |
140 |
MTX300-1G7MZ1-R-1C10 |
1×10 |
0.7 |
1.2 |
9.3 |
190 |
MTX300-1G7MZ1-R-1C16 |
1×16 |
0.7 |
1.2 |
10.3 |
270 |
MTX300-1G7MZ1-R-1C25 |
1×25 |
0.9 |
1.2 |
12.3 |
380 |
MTX300-1G7MZ1-R-1C35 |
1×35 |
0.9 |
1.2 |
13.3 |
480 |
MTX300-1G7MZ1-R-1C50 |
1×50 |
1.0 |
1.3 |
15.3 |
660 |
MTX300-1G7MZ1-R-1C70 |
1×70 |
1.1 |
1.4 |
17.3 |
900 |
MTX300-1G7MZ1-R-1C95 |
1×95 |
1.1 |
1.4 |
19.5 |
1170 |
MTX300-1G7MZ1-R-1C120 |
1×120 |
1.2 |
1.5 |
21.0 |
1410 |
MTX300-1G7MZ1-R-1C150 |
1×150 |
1.4 |
1.6 |
22.8 |
1750 |
MTX300-1G7MZ1-R-1C185 |
1×185 |
1.6 |
1.6 |
24.8 |
2160 |
MTX300-1G7MZ1-R-1C240 |
1×240 |
1.7 |
1.7 |
27.8 |
2770 |
MTX300-1G7MZ1-R-1C300 |
1×300 |
1.8 |
1.8 |
30.3 |
3440 |